3- Motor protection circuit breakers

The installation of a motor protection circuit breaker allows to prevent the breakdown of electric motors, both single-phase and three-phase. Protects against overloads (thermal protection), short circuits (magnetic protection) and phase failure. It has an on and off button to control the shot manually. You can also adjust the range of work intensity. It allows to be installed to DIN rail profile and cable connection in screw terminals. Possibility of installation of auxiliary contacts. High cutting capacity.

ERGMA

ERGMA

Rated operational voltage (Ue): 690V 50/60Hz
Rated current (Thermal protection): 1-1,6A
Circuit breaking capacity (Icu): 100kA
Poles: 3
Frequency: 50/60 Hz
Mounting: DIN rail
Protection code: IP20
Normative: IEC 60947-2, 60947-4-1
CE marking

ERGMB

ERGMB

Rated operational voltage (Ue): 690V 50/60Hz
Rated current (Thermal protection): 1,6-2,5A
Circuit breaking capacity (Icu): 100kA
Poles: 3
Frequency: 50/60 Hz
Mounting: DIN rail
Protection code: IP20
Normative: IEC 60947-2, 60947-4-1
CE marking

ERGMC

ERGMC

Rated operational voltage (Ue): 690V 50/60Hz
Rated current (Thermal protection): 2,5-4A
Circuit breaking capacity (Icu): 100kA
Poles: 3
Frequency: 50/60 Hz
Mounting: DIN rail
Protection code: IP20
Normative: IEC 60947-2, 60947-4-1
CE marking

ERGMD

ERGMD

Rated operational voltage (Ue): 690V 50/60Hz
Rated current (Thermal protection): 4-6,3A
Circuit breaking capacity (Icu): 100kA
Poles: 3
Frequency: 50/60 Hz
Mounting: DIN rail
Protection code: IP20
Normative: IEC 60947-2, 60947-4-1
CE marking

ERGME

ERGME

Rated operational voltage (Ue): 690V 50/60Hz
Rated current (Thermal protection): 6,3-10A
Circuit breaking capacity (Icu): 100kA
Poles: 3
Frequency: 50/60 Hz
Mounting: DIN rail
Protection code: IP20
Normative: IEC 60947-2, 60947-4-1
CE marking

ERGMF

ERGMF

Rated operational voltage (Ue): 690V 50/60Hz
Rated current (Thermal protection): 9-14A
Circuit breaking capacity (Icu): 100kA
Poles: 3
Frequency: 50/60 Hz
Mounting: DIN rail
Protection code: IP20
Normative: IEC 60947-2, 60947-4-1
CE marking

ERGMG

ERGMG

Rated operational voltage (Ue): 690V 50/60Hz
Rated current (Thermal protection): 10-16A
Circuit breaking capacity (Icu): 100kA
Poles: 3
Frequency: 50/60 Hz
Mounting: DIN rail
Protection code: IP20
Normative: IEC 60947-2, 60947-4-1
CE marking

ERGMH

ERGMH

Rated operational voltage (Ue): 690V 50/60Hz
Rated current (Thermal protection): 13-18A
Circuit breaking capacity (Icu): 100kA
Poles: 3
Frequency: 50/60 Hz
Mounting: DIN rail
Protection code: IP20
Normative: IEC 60947-2, 60947-4-1
CE marking

ERGMI

ERGMI

Rated operational voltage (Ue): 690V 50/60Hz
Rated current (Thermal protection): 16-20A
Circuit breaking capacity (Icu): 100kA
Poles: 3
Frequency: 50/60 Hz
Mounting: DIN rail
Protection code: IP20
Normative: IEC 60947-2, 60947-4-1
CE marking

ERGMJ

ERGMJ

Rated operational voltage (Ue): 690V 50/60Hz
Rated current (Thermal protection): 20-25A
Circuit breaking capacity (Icu): 100kA
Poles: 3
Frequency: 50/60 Hz
Mounting: DIN rail
Protection code: IP20
Normative: IEC 60947-2, 60947-4-1
CE marking

ERCM

ERCM

Auxliary contact for motor protection circuit breaker ERGM
Rated insulation voltage (Ui): 690V 50/60Hz
Conventional heating current (Ith): 6A
2 contacts: 1NO+1NC
Normative: IEC 60947-2, 60947-4-1
CE marking